Omnitron Systems Technology TV Converter Box 1000FF User Manual |
iConverter OC3FF Dual Fiber Modules
Fiber Type Distances Tx
Wavelength Wavelength
iConverter 100FF Dual Fiber Modules
iConverter 1000FF Dual Fiber Modules
iConverter OC12FF Dual Fiber Modules
Fiber Type Distances Tx
iConverter xFF Dual Fiber Modules
Rx
Fiber Type Distances
Tx
Rx
Connector
Connector
Rx
Wavelength Wavelength
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Connector
SC/SC
Connector
SC/SC
Rx Wavelength
(nm)
(Port 1
Port 2)
(Port 1
Port 2)
Connector
SFP
Rx Wavelength
(nm)
(Port 1
Port 2)
(Port 1
Port 2)
Wavelength Wavelength
(nm)
Wavelength
(nm)
(Port 1
Port 2)
(Port 1
Port 2)
Wavelength
(nm)
ST/ST
SC/SC
8622-1
ST/ST
SC/SC
(nm)
1310
1310
1310
1310
1310
1550
(nm)
1310
1310
1310
1310
1310
1550
(nm)
(nm)
1310
1310
1310
1310
1310
1550
(nm)
1310
1310
1310
1310
1310
1550
iConverter®
100FF, OC3FF, OC12FF, 1000FF and xFF
Fiber-to-Fiber Converter User Manual
MM
SM
MM
SM
MM
SM
5km
30km
5km
MM
SM
MM
SM
MM
SM
5km
30km
5km
1310
1310
1310
1310
1310
1550
1310
1310
1310
1310
1310
1550
220/550m1
220/550m1
220/550m1
12km
850
850
850
850
8660-1
8660-2
8661-1
-
-
-
-
-
-
MM
SM
MM
SM
MM
SM
220/550m1
12km
8620-1
8620-2
MM
MM
MM
SM
MM
SM
MM
SM
SM
SM
SM
SM
-
8642-0
8642-1
8642-2
8642-3
8643-2
8699-0
8681-1
8681-2
-
8622-2
850
850
8661-2
Refer to the SFP data sheet for supported transceivers.
60km
5km
60km
5km
220/550m1
34km
1310
850
1310
850
-
8622-3
SC/SC
8634-1
220/550m1
8661-3
SC/SC
8674-1
120km
120km
220/550m1
80km
34km
1310
850
1310
850
ST/SC
8630-1
iConverter 100FF Single-Fiber Modules
8681-3
SC/SC
8690-1
Port 1 (P1)
ST/SC
8670-1
iConverter OC3FF Single-Fiber Modules
220/550m1
80km
MM
SM SF
MM
5 km
20 km
5 km
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
MM
SM SF
MM
5 km
20 km
5 km
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1310
1550
1310
1310
1550
1310
1310
1310
1550
1550
1310
1310
1310
1550
iConverter OC12FF Single-Fiber Modules
12km
MM
SM SF
MM
220/550m1
20 km
1310
1310
1310
1550
1310
1310
1310
1550
1310
1550
1310
1310
1310
1550
1310
1310
8631-1
8630-2
8631-2
8632-1
8633-1
8632-2
8633-2
8635-1
8634-2
8635-2
8636-1
8637-1
8636-2
8637-2
Port 2 (P2)
34km
SM SF
MM
20 km
5 km
8671-1
8670-2
8671-2
8672-1
8673-1
8672-2
8673-2
8675-1
8674-2
8675-2
8676-1
8677-1
8676-2
8677-2
SM SF
MM
20 km
5 km
12km
8643-3
ST/SC
220/550m1
20 km
SM SF
MM
40 km
5 km
80km
8691-1
8692-1
8693-1
SM SF
MM
40 km
5 km
iConverter 1000FF Single-Fiber Modules
SM SF
SM
SM SF
SM
40 km
30 km
20 km
30 km
20 km
30 km
40 km
30 km
40 km
MM
SM SF
MM
220/550m1
20 km
850
1310
850
850
1550
850
12 km
SM SF
SM
40 km
30 km
20 km
30 km
20 km
30 km
40 km
30 km
40 km
8650-1
8651-1
8652-1
8653-1
8650-2
8651-2
8652-2
8653-2
SM SF
SM
20 km
SM SF
SM
OVERVIEW:
220/550m1
20 km
SM SF
SM
12 km
The iConverter FF modules are fiber-to-fiber media
converters providing single-mode (SM) to multimode (MM),
dual fiber to single-fiber, wavelength conversion and
fiber extension. Fixed-fiber models are available for
Ethernet, Fast Ethernet, Gigabit Ethernet and
SONET/SDH applications. Small Form Pluggable (SFP)
model is protocol transparent and also supports Fibre
Channel.
The iConverter FF media converters can be used in an
unmanaged or managed fashion. When unmanaged, they
can be installed in a chassis without a Network
Management Module (NMM). To be managed, an NMM or
a media converter with built-in management must be
installed in the same chassis.
SM
SM SF
SM
1550
1310
1310
1310
1550
850
1310
1310
1550
1310
1310
850
SM SF
20 km
SM SF
SM
SM SF
SM
12 km
162.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.
SM SF
SM
20 km
SM
SM SF
SM
12 km
SM SF
SM SF
MM
20 km
SM SF
220/550m1
40 km
SM SF
MM
1310
850
1550
850
220/550m1
40 km
SM SF
SM
1550
1310
1310
1310
1550
1310
1310
1550
1310
1310
12 km
SM SF
SM
40 km
12 km
SM SF
40 km
162.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Limitation of Warranty
FRONT PANEL DIP-SWITCH SETTINGS:
MOUNTING AND CABLE ATTACHMENT:
iConverter modules are hot-swappable and can be installed
into any chassis in the iConverter family.
Warning
FIBER-TO-FIBER SPECIFICATIONS:
LINK MODES:
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment, Buyer-
supplied interfacing, unauthorized modifications or
tampering with equipment (including repairs of equipment
by personnel not specifically authorized and certified by
Omnitron, or misuse, or operating outside the environmental
specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or
improper site preparation or maintenance.
The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
In order to accommodate different user needs, the
iConverter FF media converters support two different
linking modes.
Model Type
100FF
1000FF
OC3FF
OC12FF
xFF
1. Carefully slide the iConverter module into installation slot,
aligning the module with the installation guides. NOTE:
Ensure that the module is firmly seated against backplane.
2. Secure the module by securing panel fastener screw
(attached to module) to chassis front.
3. When using an SFP model (8699-0), insert the SFP
Fiber transceiver into the SFP receptacle on the module.
Note: The release latch of the SFP Fiber transceiver
must be in the closed position before insertion.
1000BASE-SX,
1000BASE-LX,
1000BASE-ZX,
1000BASE-BX
100BASE-FX,
1000BASE-X,
OC-3, OC-12
Fibre Channel
100BASE-FX,
100BASE-BX,
100BASE-LX
Protocols
OC-3
OC-12
Fig. 2 Front Panel Dip-Switches
Link Segment/Link Propagation “LS/LP” Dip-Switch:
This DIP-Switch has no affect. The LS function of this
DIP-Switch has been disabled to enhance compatibility
with third-party fiber optic devices. iConverter
Fiber-to-Fiber media converters normally operate in LP
mode.
Maximum
Data Rate
155Mbps
1.25Gbps
155Mbps
SC, ST,
Single-Fiber Single-Fiber
SC SC
1.25Gbps
SC,
1.25Gbps
SFP
Warranty
SC, ST,
Single-Fiber
SC
SC,
Single-Fiber
SC
This product is warranted to the original purchaser against
defects in material and workmanship for a period of 2
YEARS from the date of shipment. A LIFETIME limited
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days
from the date of shipment. To register, complete and mail
or fax the enclosed Registration Card to the indicated
address. You may also register your product on the internet
warranty period, Omnitron will, at its option, repair or replace
a product which is proven to be defective.
Fiber
Connectors
Controls
Link Propagate, Remote Fault Detection
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
LED
Power,
Remote Fault Detection Switch “RFD” Dip-Switch:
When in the Remote Fault Detection “RFD” position,
the Remote Fault Detection mode is enabled and LP
mode is disabled. When in the Normal “Norm” position
(factory setting), Remote Fault Detection is disabled
and LP mode is enabled.
Displays
Fiber Optic Link (2)
4. Attach an appropriate multimode or single-mode fiber
cable to each fiber connector. The transmit cable (Tx)
must attach to the receive side on the other device; the
receive cable (Rx) must attach to the transmit.
5. When using single-fiber (SF) models, the Tx
wavelength on one end must match the Rx wavelength
on the other and the converters must be used in
matched pairs (example: model 8670-1 must be
matched with model 8671-1).
Dimensions
Weight
W:0.85" x D:4.5" x H:2.8"
8 oz.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
UL, CE, FCC Class A,
NEBS Level 3
Compliance
Power
Requirement
(typical)
LED INDICATORS:
0.5A @
3.3VDC
0.5A @
3.3VDC
0.5A @
3.3VDC
0.5A @
3.3VDC
0.5A @
3.3VDC
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense. Omnitron
will pay the shipping charge to return the product to Buyer’s
designated US address (within the 48 contiguous states
and the District of Columbia) using Omnitron’s standard
shipping method.
LED
Color Description
Fig. 1 Link Modes
Standard:
Wide:
Storage:
0 to 50º
-40 to 60º
-40 to 80º
C
C
C
Pwr:
Yellow On--Power on
Temperature
In Link Propagate (LP) mode (sometimes referred to as
Link Loss Carry Forward), a port transmits a Link signal
only when receiving a Link on the other front-plane port,
and a loss of a received Link at one port causes the
other front-plane port to stop transmitting its link signal.
For example, P1 transmits a Link only when receiving a
Link at P2 [Fig 1(a)].
Lk/Rx (P1): Green On--Link
Lk/Rx (P2): Green On--Link
5 to 95%
(non-condensing)
Humidity
Altitude
-100m to 4000m
MTBF (hrs)
1,300,000
Technical Support:
In Remote Fault Detection (RFD) mode, a port transmits
a Link signal only when both itself and the other port are
receiving Link signals. A loss of a received Link signal
at a port is Looped-back and the port stops transmitting
a Link signal. The same loss of Link is propagated to
the other port which also stops transmitting the Link
signal. For example, the loss of Link into P2 causes
both P1 and P2 ports to stop transmission of the Link
signal [Fig 1(b)].
For help with this product, contact our Technical Support:
Phone:
Fax:
(949) 250-6510
(949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA
E-mail:
URL:
Note: Connecting two adjacent converters which
are both set to RFD is not permitted and will cause
a “deadly embrace” lockup.
Form: 040-08600-001L 3/08
Page 12
Page 7
Page 8
Page 9
Page 10
Page 11
|